FlexCase E & G

Digital Input Guide

Digital Input Specifications

Features Specification
Maximum Input Voltage 36 V
Input HIGH level DC voltage threshold 2.31 – 3.6 V
Input LOW level DC voltage threshold 0.3 – 0.99 V
Default pull Pull down
Maximum Input Leakage Current 120 nA
PWM Signal Frequency 50 MHz
Signal Conditioning and Protection Voltage Limiting, Voltage Filtering, Current Limiting

Digital Inputs (DI) Information

Pull up / Pull Down Configuration:

  • By default all the digital inputs are pulled LOW.  The Digital Input Pull-Up Enable pin (DI_Hi_Pull_EN) is used to configure the pull on the digital inputs.
    • For Example, in FCE 2.1, Setting PTE14 HIGH will pull up the digital inputs 1-6. Refer datasheet for more Info.
  • Each digital input is equipped with signal conditioning and protection features, including Voltage Limiting, Voltage Filtering, and Current Limiting, to safeguard the MCU.
  • Make sure the input voltage is between the threshold range mentioned above for HIGH and LOW values.