FlexCase E & G
Digital Input Guide
Digital Input Specifications
Features | Specification |
---|---|
Maximum Input Voltage | 36 V |
Input HIGH level DC voltage threshold | 2.31 – 3.6 V |
Input LOW level DC voltage threshold | 0.3 – 0.99 V |
Default pull | Pull down |
Maximum Input Leakage Current | 120 nA |
PWM Signal Frequency | 50 MHz |
Signal Conditioning and Protection | Voltage Limiting, Voltage Filtering, Current Limiting |
Digital Inputs (DI) Information
Pull up / Pull Down Configuration:
- By default all the digital inputs are pulled LOW. The Digital Input Pull-Up Enable pin (DI_Hi_Pull_EN) is used to configure the pull on the digital inputs.
- For Example, in FCE 2.1, Setting PTE14 HIGH will pull up the digital inputs 1-6. Refer datasheet for more Info.
- Each digital input is equipped with signal conditioning and protection features, including Voltage Limiting, Voltage Filtering, and Current Limiting, to safeguard the MCU.
- Make sure the input voltage is between the threshold range mentioned above for HIGH and LOW values.